EDF Energy Electricity Meter Points API

The Electricity Meter Points API from EDF Energy — 2 operation(s) for electricity meter points.

Operations 2

GET /v1/electricity-meter-points/{mpan}/ Get electricity meter point #
GET /v1/electricity-meter-points/{mpan}/meters/{serial_number}/consumption/ List consumption for an electricity meter #

Work with this as data

Every API here is available over the APIs.io API and to AI agents over MCP.

MCP server

One button, every client — Claude, Cursor, VS Code and the rest.

https://apis.io/mcp

Tools for apis

7 MCP tools reach this
  • find_apisBrowse and filter every API in the catalog.
  • get_api_artifactsOne API's artifacts, grouped by type.
  • get_openapiThe primary OpenAPI for this API.
  • find_similar_apisAPIs that look like this one.
  • apis_io_searchSTART HERE — APIs, providers and tags for one query, each with its total.
  • resolveTurn a domain, URL or GitHub org into the provider it belongs to.
  • find_cohortsEvery scored population of providers in the catalog.
All 92 tools →

Call it yourself

curl for this page
This API
curl "https://apis.io/api/v1/apis/edf-energy-electricity-meter-points-api"
All apis
curl "https://apis.io/api/v1/apis?limit=25"

Discovery needs no key. Ratings and market analysis are Pro.

Get an API key

Free tier, no form to fill in. Signing in shares your email address with us — we store it to create your key and to recognise you if you sign in with another provider. See our Privacy Policy and Terms.

A second provider on the same verified email joins the account you already have.

OpenAPI Specification

edf-energy-electricity-meter-points-api-openapi.yml Raw ↑
openapi: 3.2.0
info:
  title: Kraken Electricity Meter Points API
  version: v1
servers:
- url: https://api.edfgb-kraken.energy/v1/
  description: Base URL declared by the provider in apis.yml (roadmap#122).
tags:
- name: Electricity Meter Points
paths:
  /v1/electricity-meter-points/{mpan}/:
    get:
      operationId: GetElectricityMeterPoint
      description: Retrieve the details of a meter-point. This endpoint can be used to get the GSP of a given meter-point.
      parameters:
      - in: path
        name: mpan
        schema:
          type: string
        required: true
      tags:
      - Electricity Meter Points
      security:
      - KeyAuthentication: []
      - DRFKrakenTokenAuthentication: []
      responses:
        '200':
          content:
            application/json:
              schema:
                $ref: '#/components/schemas/ElectricityMeterPoint'
              examples:
                DetailsOfAnElectricityMeter-point:
                  value:
                    gsp: _H
                    mpan: '2000024512368'
                    profile_class: 1
                  summary: Details of an electricity meter-point
          description: ''
      summary: Get electricity meter point
      x-summary-source: derived
      x-operation-id-source: normalized
      x-operation-id-original: Get Electricity Meter Point
  /v1/electricity-meter-points/{mpan}/meters/{serial_number}/consumption/:
    get:
      operationId: ListConsumptionForAnElectricityMeter
      description: 'Return a list of consumption values (in kWh) for half-hour periods for a given meter-point and meter. WARNING: Half-hourly consumption data is only available for smart meters. Requests for consumption data for non-smart meters will return an empty response payload.'
      parameters:
      - name: group_by
        required: false
        in: query
        description: 'Aggregates consumption over a specified time period. A day is considered to start and end at midnight in the server’s timezone. The default is that consumption is returned in half-hour periods. Accepted values are: * ‘hour’ * ‘day’ * ‘week’ * ‘month’ * ‘quarter’.'
        schema:
          type: string
      - in: path
        name: mpan
        schema:
          type: string
        required: true
      - name: order_by
        required: false
        in: query
        description: 'Ordering of results returned. Default is that results are returned in reverse order from latest available figure. Valid values: * ‘period’, to give results ordered forward. * ‘-period’, (default), to give results ordered from most recent backwards.'
        schema:
          type: string
      - name: page
        required: false
        in: query
        description: A page number within the paginated result set.
        schema:
          type: integer
      - name: page_size
        required: false
        in: query
        description: Page size of returned results. Default is 100, maximum is 25000 to give a full year of half-hourly consumption details.
        schema:
          type: integer
      - name: period_from
        required: false
        in: query
        description: Show results from the given datetime (inclusive). This parameter can be provided on its own.
        schema:
          type: datetime
      - name: period_to
        required: false
        in: query
        description: Show results up to the given datetime (exclusive). You must also provide the period_from parameter in order to create a range.
        schema:
          type: datetime
      - in: path
        name: serial_number
        schema:
          type: string
        required: true
      tags:
      - Electricity Meter Points
      security:
      - KeyAuthentication: []
      - DRFKrakenTokenAuthentication: []
      responses:
        '200':
          content:
            application/json:
              schema:
                $ref: '#/components/schemas/PaginatedConsumptionList'
              examples:
                ListOfConsumptionValues:
                  value:
                    count: 123
                    next: https://api.edfgb-kraken.energy/v1/electricity-meter-points/S1212345678901/meters/Z16N389556/consumption/?page=4
                    previous: https://api.edfgb-kraken.energy/v1/electricity-meter-points/S1212345678901/meters/Z16N389556/consumption/?page=2
                    results:
                    - - consumption: 0.063
                        interval_start: 2018-05-19T00:30:00+0100
                        interval_end: 2018-05-19T01:00:00+0100
                      - consumption: 0.071
                        interval_start: 2018-05-19T00:00:00+0100
                        interval_end: 2018-05-19T00:30:00+0100
                      - consumption: 0.073
                        interval_start: 2018-05-18T23:30:00+0100
                        interval_end: 2018-05-18T00:00:00+0100
                  summary: List of consumption values
          description: ''
      summary: List consumption for an electricity meter
      x-summary-source: derived
      x-operation-id-source: normalized
      x-operation-id-original: List consumption for an electricity meter
components:
  schemas:
    PaginatedConsumptionList:
      type: object
      required:
      - count
      - results
      properties:
        count:
          type: integer
          example: 123
        next:
          type:
          - string
          - 'null'
          format: uri
          example: https://api.edfgb-kraken.energy/v1/electricity-meter-points/S1212345678901/meters/Z16N389556/consumption/?page=4
        previous:
          type:
          - string
          - 'null'
          format: uri
          example: https://api.edfgb-kraken.energy/v1/electricity-meter-points/S1212345678901/meters/Z16N389556/consumption/?page=2
        results:
          type: array
          items:
            $ref: '#/components/schemas/Consumption'
    Consumption:
      type: object
      properties:
        consumption:
          type: string
          readOnly: true
        interval_start:
          type: string
          format: date-time
        interval_end:
          type: string
          format: date-time
      required:
      - consumption
      - interval_end
      - interval_start
    BespokePPSTariffRates:
      type: object
      properties:
        standing_charge:
          type: string
          format: decimal
          pattern: ^-?\d{0,7}(?:\.\d{0,5})?$
          title: The value in pence per day of the charge (excluding VAT).
        unit_rate:
          type: string
          format: decimal
          pattern: ^-?\d{0,7}(?:\.\d{0,5})?$
          title: The value in pence per kWh of the charge (excluding VAT).
          description: This field should be used for gas meters.
        unit_rates:
          type: array
          items:
            $ref: '#/components/schemas/BespokeElectricityUnitRate'
          title: List of the value in pence per kWh of the charges (excluding VAT).
          description: For elec meters, the unit rates are provided on a per register basis in this array.
        payment_method:
          enum:
          - DD
          - NDD
          - PP
          type: string
          description: '* `DD` - Direct Debit

            * `NDD` - Non-Direct Debit

            * `PP` - Prepayment'
          x-spec-enum-id: 362e54c421bbcaea
          title: The payment method for the rate.
      required:
      - payment_method
    Address:
      type: object
      properties:
        address_line_1:
          type: string
          maxLength: 512
        address_line_2:
          type: string
          maxLength: 512
        address_line_3:
          type: string
          maxLength: 512
        town:
          type: string
          maxLength: 512
        county:
          type: string
          maxLength: 512
        postcode:
          type: string
          maxLength: 8
        delivery_point_identifier:
          type: string
          maxLength: 11
      required:
      - address_line_1
      - postcode
    ElectricityMeterPoint:
      type: object
      properties:
        tariff_code:
          type: string
          title: The tariff code as stored by the supplier.
          description: Must match an available tariff on the 'sold_at' datetime for the authenticating partner. Required if no 'quote_request_code' is supplied.
          maxLength: 255
        quoted_product_id:
          type: integer
          description: The ID of the market supply quoted product returned by the 'QuoteNewMeterPoints' or 'QuoteNewMeterPointsOnBespokeProducts' mutation which was selected by the customer for this meter point. Required if a 'quote_request_code' is supplied.
        address:
          $ref: '#/components/schemas/Address'
        current_supplier_name:
          type: string
          maxLength: 255
        current_supplier_tariff:
          type: string
          maxLength: 255
        has_smart_meter:
          type: boolean
          title: Whether a smart meter is installed. The default is 'false'.
        consumption_standard:
          type: integer
          maximum: 500000
          minimum: 1
          title: The expected annual consumption for the standard register in kWh.
          description: Required if standard tariff.
        unit_rate_uplift:
          type: string
          format: decimal
          pattern: ^-?\d{0,4}(?:\.\d{0,3})?$
          title: The amount to be added to the unit rate as commission (a string, pence per kWh).
        standing_charge_uplift:
          type: string
          format: decimal
          pattern: ^-?\d{0,4}(?:\.\d{0,3})?$
          title: The amount to be added to the standing charge as commission (a string, pence per day).
        fixed_tpi_fee:
          type: integer
          minimum: 0
        quote:
          $ref: '#/components/schemas/Quote'
        bespoke_tariff_rates:
          allOf:
          - $ref: '#/components/schemas/BespokeTariffRates'
          title: A json object containing bespoke tariff rates, if applicable.
          description: Cannot be used in conjunction with 'bespoke_pps_tariff_rates'.
        bespoke_pps_tariff_rates:
          type: array
          items:
            $ref: '#/components/schemas/BespokePPSTariffRates'
          description: 'If applicable, must contain two objects: one for direct debit bespoke and another for non-direct debit bespoke rates. Cannot be used in conjunction with ''bespoke_tariff_rates''.'
          maxItems: 2
          minItems: 0
        meter_type:
          enum:
          - CREDIT
          - PREPAYMENT
          type: string
          x-spec-enum-id: ebae2e9cf73bc01e
          default: CREDIT
          description: 'The default is ''CREDIT'', which represents any kind of traditional credit meter or smart meter. This field is mandatory for traditional prepay meters, for which the value ''PREPAYMENT'' should be used.


            * `CREDIT` - CREDIT

            * `PREPAYMENT` - PREPAYMENT'
        preferred_ssd:
          type: string
          format: date
        mpan:
          type: string
          title: The meter-point identifier.
          maxLength: 13
        is_half_hourly:
          type: boolean
          title: Whether the meter point should be enrolled as a half hourly meter point
          description: Required to start the CoS Gain correctly for half hourly customers.
        consumption_day:
          type: integer
          maximum: 500000
          minimum: 1
          title: The expected annual consumption for the day/peak register in kWh.
          description: Required if eco7 or three-rate tariff.
        consumption_night:
          type: integer
          maximum: 500000
          minimum: 0
          title: The expected annual consumption for the night/off-peak register in kWh.
          description: Required if eco7 or three-rate tariff.
        consumption_off_peak:
          type: integer
          maximum: 500000
          minimum: 0
          title: The expected annual consumption for the additional off-peak register in kWh.
          description: Required if three-rate tariff.
        export_details:
          allOf:
          - $ref: '#/components/schemas/ExportDetails'
          title: The generation details for the meter-point.
      required:
      - quote
    BespokeTariffRates:
      type: object
      properties:
        standing_charge:
          type: string
          format: decimal
          pattern: ^-?\d{0,7}(?:\.\d{0,5})?$
          title: The value in pence per day of the charge (excluding VAT).
        unit_rate:
          type: string
          format: decimal
          pattern: ^-?\d{0,7}(?:\.\d{0,5})?$
          title: The value in pence per kWh of the charge (excluding VAT).
          description: This field should be used for gas meters.
        unit_rates:
          type: array
          items:
            $ref: '#/components/schemas/BespokeElectricityUnitRate'
          title: List of the value in pence per kWh of the charges (excluding VAT).
          description: For elec meters, the unit rates are provided on a per register basis in this array.
    ExportDetails:
      type: object
      properties:
        import_mpan:
          type: string
          description: The import MPAN.
          maxLength: 13
        site_contact_name:
          type: string
          description: The name of the site contact.
        site_contact_phone:
          type: string
          description: The phone number of the site contact.
        site_contact_email:
          type: string
          format: email
          description: The email address of the site contact.
        installations:
          type: array
          items:
            $ref: '#/components/schemas/Installation'
    BespokeElectricityUnitRate:
      type: object
      properties:
        rate_type:
          enum:
          - STANDARD
          - ECO7_DAY
          - ECO7_NIGHT
          - OFF_PEAK
          - PEAK
          - WEEKDAY
          - OFF_PEAK_WEEKENDS
          - WEEKENDS_OTHER
          - SUMMER
          - SUMMER_PEAK
          - SUMMER_OFF_PEAK
          - WINTER
          - WINTER_PEAK
          - WINTER_OFF_PEAK
          - NUCLEAR_RAB
          - SUMMER_WEEKENDS_OFF_PEAK_WINTER
          - TNUOS
          - CAPACITY_MARKET
          - HMC_GUARANTEE_ADVANCE
          - HMC_GUARANTEE_FULL
          - EV_DEVICE
          - EV_DEVICE_PEAK
          - EV_DEVICE_OFF_PEAK
          type: string
          x-spec-enum-id: 382cc620726bec21
          title: The rate type of the unit rate.
          description: 'If the register_identifier is not provided, the rate type must be provided instead.


            * `STANDARD` - Standard rate (pence per kWh)

            * `ECO7_DAY` - Day (or peak) rate (pence per kWh)

            * `ECO7_NIGHT` - Night (or off-peak) rate (pence per kWh)

            * `OFF_PEAK` - Additional off-peak rate for three-rate tariffs (pence per kWh)

            * `PEAK` - Peak rate (pence per kWh) for business tariffs

            * `WEEKDAY` - Weekday rate (pence per kWh) for business tariffs

            * `OFF_PEAK_WEEKENDS` - Off peak weekend rate (pence per kWh) for business tariffs

            * `WEEKENDS_OTHER` - Weekend rate (pence per kWh) for business tariffs

            * `SUMMER` - Summer rate (pence per kWh) for business tariffs

            * `SUMMER_PEAK` - Summer peak rate (pence per kWh) for two-rate tariffs

            * `SUMMER_OFF_PEAK` - Summer off-peak rate (pence per kWh) for two-rate tariffs

            * `WINTER` - Winter rate (pence per kWh) for business tariffs

            * `WINTER_PEAK` - Winter peak rate (pence per kWh) for two-rate tariffs

            * `WINTER_OFF_PEAK` - Winter off-peak rate (pence per kWh) for two-rate tariffs

            * `NUCLEAR_RAB` - Nuclear RAB rate (pence per day) for business tariffs

            * `SUMMER_WEEKENDS_OFF_PEAK_WINTER` - A rate that applies during summer, weekends and off-peak in winter periods(pence per kWh) for business tariffs

            * `TNUOS` - TNUoS rate (pence per day) for business tariffs

            * `CAPACITY_MARKET` - Capacity Market rate (pence per day) for business tariffs

            * `HMC_GUARANTEE_ADVANCE` - Hourly Matching Credit Guarantee Advance rate (pence per kWh) for business tariffs

            * `HMC_GUARANTEE_FULL` - Hourly Matching Credit Guarantee Full rate (pence per kWh) for business tariffs

            * `EV_DEVICE` - Electric vehicle device rate (pence per kWh) for sub-meter billing

            * `EV_DEVICE_PEAK` - Electric vehicle device peak rate (pence per kWh) for sub-meter billing

            * `EV_DEVICE_OFF_PEAK` - Electric vehicle device off-peak rate (pence per kWh) for sub-meter billing'
        unit_rate:
          type: string
          format: decimal
          pattern: ^-?\d{0,7}(?:\.\d{0,5})?$
          title: The value in pence per kWh of the charge (excluding VAT).
          description: This field should be used for gas meters.
        payment_method:
          enum:
          - DD
          - NDD
          - PP
          type: string
          x-spec-enum-id: 84f5b0df65c6e1bb
          title: The value in pence per kWh of the charge (excluding VAT).
          description: 'This field should be used for gas meters.


            * `DD` - DD

            * `NDD` - NDD

            * `PP` - PP'
      required:
      - unit_rate
    Quote:
      type: object
      properties:
        annual_payment:
          type: integer
          minimum: 0
          title: The estimated annual payment for this meter-point based on consumption.
          description: This value must be provided in pence. For business quotes, the price is exclusive of VAT, while for non-business quotes, it should be inclusive of VAT.
      required:
      - annual_payment
    Installation:
      type: object
      properties:
        fit_id:
          type: string
          description: The Feed-in Tariff ID.
        rego_id:
          type: string
          description: The REGO accreditation number.
        technology_type:
          enum:
          - LkUp_Generator_TypesCombined
          - Bio Diesel (Oil)
          - Bio Diesel (Oil) CHP
          - Bio Gas (AD)
          - Bio Gas (AD) CHP
          - Bio Gas (Landfill)
          - Bio Mass (Wood)
          - Bio Mass (Wood) CHP
          - Bio Methane
          - Geothermal (Airsource)
          - Geothermal (Groundsource)
          - Geothermal (Watersource)
          - Hydro (Dam - Drinking Water)
          - Hydro (Dam)
          - Hydro (Pumped Storage)
          - Hydro (Run-of-River)
          - Hydro (Sewerage Treatment)
          - Hydro (Tidal)
          - Hydro (Water Treatment)
          - Hydro (Wave)
          - Solar PV (Building)
          - Solar PV (Field - Multi Use)
          - Solar PV (Field - Single Use)
          - Solar Thermal
          - Wind (Offshore)
          - Wind (Onshore)
          - AD
          - CHP
          - Hydro
          - Solar
          - Wind
          type: string
          x-spec-enum-id: da0f319a77bff5cf
          description: 'The technology type for the installation. If there are multiple technologies at one site then provide multiple installations.


            * `LkUp_Generator_TypesCombined` - LkUp_Generator_TypesCombined

            * `Bio Diesel (Oil)` - Bio Diesel (Oil)

            * `Bio Diesel (Oil) CHP` - Bio Diesel (Oil) CHP

            * `Bio Gas (AD)` - Bio Gas (AD)

            * `Bio Gas (AD) CHP` - Bio Gas (AD) CHP

            * `Bio Gas (Landfill)` - Bio Gas (Landfill)

            * `Bio Mass (Wood)` - Bio Mass (Wood)

            * `Bio Mass (Wood) CHP` - Bio Mass (Wood) CHP

            * `Bio Methane` - Bio Methane

            * `Geothermal (Airsource)` - Geothermal (Airsource)

            * `Geothermal (Groundsource)` - Geothermal (Groundsource)

            * `Geothermal (Watersource)` - Geothermal (Watersource)

            * `Hydro (Dam - Drinking Water)` - Hydro (Dam - Drinking Water)

            * `Hydro (Dam)` - Hydro (Dam)

            * `Hydro (Pumped Storage)` - Hydro (Pumped Storage)

            * `Hydro (Run-of-River)` - Hydro (Run-of-River)

            * `Hydro (Sewerage Treatment)` - Hydro (Sewerage Treatment)

            * `Hydro (Tidal)` - Hydro (Tidal)

            * `Hydro (Water Treatment)` - Hydro (Water Treatment)

            * `Hydro (Wave)` - Hydro (Wave)

            * `Solar PV (Building)` - Solar PV (Building)

            * `Solar PV (Field - Multi Use)` - Solar PV (Field - Multi Use)

            * `Solar PV (Field - Single Use)` - Solar PV (Field - Single Use)

            * `Solar Thermal` - Solar Thermal

            * `Wind (Offshore)` - Wind (Offshore)

            * `Wind (Onshore)` - Wind (Onshore)

            * `AD` - AD

            * `CHP` - CHP

            * `Hydro` - Hydro

            * `Solar` - Solar

            * `Wind` - Wind'
        capacity_in_kw:
          type: string
          format: decimal
          pattern: ^-?\d{0,11}(?:\.\d{0,2})?$
          title: The total capacity of the installation in kW.
        estimated_annual_generation_in_kwh:
          type: string
          format: decimal
          pattern: ^-?\d{0,11}(?:\.\d{0,2})?$
          title: The estimated annual generation of the installation in kWh.
      required:
      - capacity_in_kw
      - estimated_annual_generation_in_kwh
      - technology_type
  securitySchemes:
    AccountUserAPIKeyAuthentication:
      type: http
      scheme: basic
      description: Token-based authentication where token is passed as the username for basic auth
    AffiliateAuthentication:
      type: http
      scheme: basic
      description: Basic authentication for affiliate organisations
    DRFKrakenTokenAuthentication:
      type: apiKey
      in: header
      name: Authorization
      description: JWT-based authentication
    KeyAuthentication:
      type: apiKey
      in: header
      name: Authorization
      description: Token-based authentication with required prefix "Token "
    PartnerUserOnlyAuthentication:
      type: http
      scheme: basic
      description: Basic authentication for partner organisations