Demiton · Schema

inspection_test_result contract v1

Soil and concrete test results (AS 1289, AS 1012).

CompanyConstructionCivil EngineeringProject ManagementComplianceMCPArtificial IntelligenceOpen Contracting

Properties

Name Type Description
outlier boolean whether the result was treated as an outlier
project string the project whose works were tested
complies boolean whether the result meets the specification
material string what was tested, e.g. soil, concrete or aggregate
specimen string the specimen type and geometry, or the mould used
test_lot string the test lot the result belongs to
tested_on string the date the test was performed
accredited boolean whether the laboratory is accredited for the test
laboratory string the laboratory that did the test
sampled_at string when the sample was taken
external_id string the laboratory report or sample id
result_name string the quantity measured, e.g. compressive strength or dry density ratio
result_unit string the unit of the result, e.g. MPa or percent
test_method string the method designation and year, e.g. AS 1012.9:2014
result_value number the measured result
curing_regime string how the concrete specimen was cured
defects_noted string specimen defects recorded at test
test_location string where on the works the test or sample was taken
drawing_number string the drawing the test lot was built to, as the drawing register numbers it; the rework drift rule joins the lot to the drawing's revision history on it
field_moisture number the field moisture measured
mix_identifier string the concrete mix or supply identifier
age_at_test_days integer the specimen's age when tested
competent_person string the competent person responsible for the test
drawing_revision string the revision of that drawing the test lot was built to, as the drawing register labels it; the rework drift rule compares it with the revision current on the lot's work date
inspection_level string the declared inspection and testing level, Level 1 or Level 2
field_dry_density number the field dry density measured
testing_authority string whether a GITA or a GTA did the testing
specification_value number the acceptance criterion the result is judged against
reference_dry_density number the reference maximum dry density
optimum_moisture_content number the optimum moisture content
View JSON Schema on GitHub

JSON Schema

demiton-io-inspection_test_result-v1-schema.json Raw ↑
{
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "$id": "https://docs.demiton.io/registers/inspection_test_result/v1.json",
  "title": "inspection_test_result contract v1",
  "type": "object",
  "required": [
    "material",
    "project",
    "result_unit",
    "result_value",
    "test_method",
    "tested_on"
  ],
  "properties": {
    "outlier": {
      "type": "boolean",
      "description": "whether the result was treated as an outlier",
      "x-demiton-requiredness": "optional"
    },
    "project": {
      "type": "string",
      "description": "the project whose works were tested",
      "x-demiton-requiredness": "required",
      "x-demiton-reference": true
    },
    "complies": {
      "type": "boolean",
      "description": "whether the result meets the specification",
      "x-demiton-requiredness": "optional"
    },
    "material": {
      "type": "string",
      "description": "what was tested, e.g. soil, concrete or aggregate",
      "x-demiton-requiredness": "required"
    },
    "specimen": {
      "type": "string",
      "description": "the specimen type and geometry, or the mould used",
      "x-demiton-requiredness": "optional"
    },
    "test_lot": {
      "type": "string",
      "description": "the test lot the result belongs to",
      "x-demiton-requiredness": "optional"
    },
    "tested_on": {
      "type": "string",
      "description": "the date the test was performed",
      "x-demiton-requiredness": "required",
      "x-demiton-unit": "day",
      "format": "date",
      "x-demiton-type": "date"
    },
    "accredited": {
      "type": "boolean",
      "description": "whether the laboratory is accredited for the test",
      "x-demiton-requiredness": "optional"
    },
    "laboratory": {
      "type": "string",
      "description": "the laboratory that did the test",
      "x-demiton-requiredness": "optional"
    },
    "sampled_at": {
      "type": "string",
      "description": "when the sample was taken",
      "x-demiton-requiredness": "optional",
      "format": "date-time",
      "x-demiton-type": "datetime"
    },
    "external_id": {
      "type": "string",
      "description": "the laboratory report or sample id",
      "x-demiton-requiredness": "optional"
    },
    "result_name": {
      "type": "string",
      "description": "the quantity measured, e.g. compressive strength or dry density ratio",
      "x-demiton-requiredness": "optional"
    },
    "result_unit": {
      "type": "string",
      "description": "the unit of the result, e.g. MPa or percent",
      "x-demiton-requiredness": "required"
    },
    "test_method": {
      "type": "string",
      "description": "the method designation and year, e.g. AS 1012.9:2014",
      "x-demiton-requiredness": "required"
    },
    "result_value": {
      "type": "number",
      "description": "the measured result",
      "x-demiton-requiredness": "required",
      "x-demiton-type": "decimal"
    },
    "curing_regime": {
      "type": "string",
      "description": "how the concrete specimen was cured",
      "x-demiton-requiredness": "optional"
    },
    "defects_noted": {
      "type": "string",
      "description": "specimen defects recorded at test",
      "x-demiton-requiredness": "optional"
    },
    "test_location": {
      "type": "string",
      "description": "where on the works the test or sample was taken",
      "x-demiton-requiredness": "optional"
    },
    "drawing_number": {
      "type": "string",
      "description": "the drawing the test lot was built to, as the drawing register numbers it; the rework drift rule joins the lot to the drawing's revision history on it",
      "x-demiton-requiredness": "optional",
      "x-demiton-reference": true
    },
    "field_moisture": {
      "type": "number",
      "description": "the field moisture measured",
      "x-demiton-requiredness": "optional",
      "x-demiton-unit": "percent",
      "x-demiton-type": "decimal"
    },
    "mix_identifier": {
      "type": "string",
      "description": "the concrete mix or supply identifier",
      "x-demiton-requiredness": "optional"
    },
    "age_at_test_days": {
      "type": "integer",
      "description": "the specimen's age when tested",
      "x-demiton-requiredness": "optional",
      "x-demiton-unit": "days"
    },
    "competent_person": {
      "type": "string",
      "description": "the competent person responsible for the test",
      "x-demiton-requiredness": "optional",
      "x-demiton-reference": true
    },
    "drawing_revision": {
      "type": "string",
      "description": "the revision of that drawing the test lot was built to, as the drawing register labels it; the rework drift rule compares it with the revision current on the lot's work date",
      "x-demiton-requiredness": "optional"
    },
    "inspection_level": {
      "type": "string",
      "description": "the declared inspection and testing level, Level 1 or Level 2",
      "x-demiton-requiredness": "optional"
    },
    "field_dry_density": {
      "type": "number",
      "description": "the field dry density measured",
      "x-demiton-requiredness": "optional",
      "x-demiton-unit": "t/m3",
      "x-demiton-type": "decimal"
    },
    "testing_authority": {
      "type": "string",
      "description": "whether a GITA or a GTA did the testing",
      "x-demiton-requiredness": "optional"
    },
    "specification_value": {
      "type": "number",
      "description": "the acceptance criterion the result is judged against",
      "x-demiton-requiredness": "optional",
      "x-demiton-type": "decimal"
    },
    "reference_dry_density": {
      "type": "number",
      "description": "the reference maximum dry density",
      "x-demiton-requiredness": "optional",
      "x-demiton-unit": "t/m3",
      "x-demiton-type": "decimal"
    },
    "optimum_moisture_content": {
      "type": "number",
      "description": "the optimum moisture content",
      "x-demiton-requiredness": "optional",
      "x-demiton-unit": "percent",
      "x-demiton-type": "decimal"
    }
  },
  "x-demiton-register-type": "inspection_test_result",
  "x-demiton-contract-version": "1.2.0",
  "x-demiton-store": "tenant",
  "x-demiton-axes": [],
  "x-demiton-measures": [],
  "x-demiton-provenance": {
    "standards": [
      {
        "code": "AS 1012 series",
        "title": "Methods of testing concrete",
        "access": "paywalled_secondary",
        "clause": "AS 1012.9:2014 cl 4 (specimen defects to be noted per cl 11 and 12)",
        "region": "Australia",
        "edition": "series; parts separately dated (e.g. AS 1012.1:2014, 1012.8.1:2014, 1012.9:2014, 1012.14:2018)",
        "checked_on": "2026-09-14"
      },
      {
        "code": "AS 1289 series",
        "title": "Methods of testing soils for engineering purposes",
        "access": "paywalled_secondary",
        "clause": "AS 1289.5.1.1:2017 cl 3.1 (competent person)",
        "region": "Australia",
        "edition": "series; umbrella AS 1289.0:2014; parts separately dated (e.g. AS 1289.5.1.1:2017, 5.2.1:2017, 5.4.1:2007, 5.8.1:2007)",
        "checked_on": "2026-09-14"
      },
      {
        "code": "AS 1379",
        "title": "Specification and supply of concrete",
        "access": "public_summary",
        "region": "Australia",
        "edition": "edition conflicting: index lists 2007 as current, a reseller advertised AS 1379:2026 (unverified)",
        "checked_on": "2026-09-14"
      },
      {
        "code": "AS 3798-2007",
        "title": "Guidelines on earthworks for commercial and residential developments",
        "access": "public_summary",
        "clause": "s 3.5 site records; s 8.2-8.7 (Level 1/2, GITA, GTA, statements of compliance, frequency); App C4 outliers",
        "region": "Australia",
        "edition": "2007 incorporating Amd 1 (2008)",
        "checked_on": "2026-09-14"
      },
      {
        "code": "NATA accreditation",
        "title": "National Association of Testing Authorities accreditation",
        "access": "public_summary",
        "region": "Australia",
        "edition": "current",
        "checked_on": "2026-09-14"
      },
      {
        "code": "EN 12350 / EN 12390 / EN 13286",
        "title": "European concrete and unbound-mixture test standards",
        "access": "public_summary",
        "region": "European Union",
        "edition": "EN editions as adopted by BS/I.S.",
        "checked_on": "2026-09-14"
      },
      {
        "code": "ISO/IEC 17025:2017",
        "title": "General requirements for the competence of testing and calibration laboratories",
        "access": "public_summary",
        "clause": "cl 7 process requirements (no sub-clause cited)",
        "region": "International",
        "edition": "2017",
        "checked_on": "2026-09-14"
      },
      {
        "code": "NZS 3112:1986",
        "title": "Methods of test for concrete",
        "access": "public_summary",
        "region": "New Zealand",
        "edition": "1986 (parts 3112.1, 3112.2)",
        "checked_on": "2026-09-14"
      },
      {
        "code": "NZS 4402:1986",
        "title": "Methods of testing soils for civil engineering purposes",
        "access": "public_summary",
        "region": "New Zealand",
        "edition": "1986 (parts 4402.1, 4402.4.1.1, 4402.5.1.1)",
        "checked_on": "2026-09-14"
      },
      {
        "code": "BS EN 12350 / BS EN 12390",
        "title": "Testing fresh concrete / Testing hardened concrete",
        "access": "public_summary",
        "region": "United Kingdom",
        "edition": "e.g. BS EN 12350-1:2019, -2:2019; BS EN 12390-1:2021, -2:2019, -3:2019, -4:2025, -5:2019",
        "checked_on": "2026-09-14"
      },
      {
        "code": "BS EN 13286 / BS 1377",
        "title": "Unbound and hydraulically bound mixtures / Methods of test for soils for civil engineering purposes",
        "access": "public_summary",
        "region": "United Kingdom",
        "edition": "BS EN 13286-1:2021, BS EN 13286-2:2010, BS 1377-9:2025",
        "checked_on": "2026-09-14"
      },
      {
        "code": "ASTM C172 / C31 / C39 / C143 / C231",
        "title": "ASTM fresh and hardened concrete sampling and test methods",
        "access": "public_summary",
        "region": "United States",
        "edition": "C172/C172M-25, C31/C31M-26a, C39/C39M-24, C143/C143M-26a, C231/C231M-26",
        "checked_on": "2026-09-14"
      },
      {
        "code": "ASTM D698 / D1557 / D6938 / D2216",
        "title": "ASTM soil compaction, nuclear density and water content methods",
        "access": "public_summary",
        "region": "United States",
        "edition": "D698-12, D1557-12, D6938-23, D2216-19",
        "checked_on": "2026-09-14"
      }
    ]
  },
  "description": "Soil and concrete test results (AS 1289, AS 1012).",
  "x-demiton-contract-url": "https://docs.demiton.io/registers/inspection_test_result/",
  "x-demiton-register-catalog": "https://docs.demiton.io/concepts/register-catalog"
}

Work with this as data

Every JSON Schema here is available over the APIs.io API and to AI agents over MCP.

MCP server

One button, every client — Claude, Cursor, VS Code and the rest.

https://apis.io/mcp

Tools for schemas

4 MCP tools reach this
  • find_json_schemasBrowse and filter every JSON Schema in the catalog.
  • apis_io_searchSTART HERE — APIs, providers and tags for one query, each with its total.
  • resolveTurn a domain, URL or GitHub org into the provider it belongs to.
  • find_cohortsEvery scored population of providers in the catalog.
All 92 tools →

Call it yourself

curl for this page
This JSON Schema
curl "https://apis.io/api/v1/json-schemas/demiton-io-inspection_test_result-v1"
All schemas
curl "https://apis.io/api/v1/json-schemas?limit=25"

Calls without X-API-Key need no key. Calls with it need a paid plan — get a key.

Get an API key

Free tier, no form to fill in. Signing in shares your email address with us — we store it to create your key and to recognise you if you sign in with another provider. See our Privacy Policy and Terms.