Demiton · Schema
inspection_test_result contract v1
Soil and concrete test results (AS 1289, AS 1012).
CompanyConstructionCivil EngineeringProject ManagementComplianceMCPArtificial IntelligenceOpen Contracting
Properties
| Name | Type | Description |
|---|---|---|
| outlier | boolean | whether the result was treated as an outlier |
| project | string | the project whose works were tested |
| complies | boolean | whether the result meets the specification |
| material | string | what was tested, e.g. soil, concrete or aggregate |
| specimen | string | the specimen type and geometry, or the mould used |
| test_lot | string | the test lot the result belongs to |
| tested_on | string | the date the test was performed |
| accredited | boolean | whether the laboratory is accredited for the test |
| laboratory | string | the laboratory that did the test |
| sampled_at | string | when the sample was taken |
| external_id | string | the laboratory report or sample id |
| result_name | string | the quantity measured, e.g. compressive strength or dry density ratio |
| result_unit | string | the unit of the result, e.g. MPa or percent |
| test_method | string | the method designation and year, e.g. AS 1012.9:2014 |
| result_value | number | the measured result |
| curing_regime | string | how the concrete specimen was cured |
| defects_noted | string | specimen defects recorded at test |
| test_location | string | where on the works the test or sample was taken |
| drawing_number | string | the drawing the test lot was built to, as the drawing register numbers it; the rework drift rule joins the lot to the drawing's revision history on it |
| field_moisture | number | the field moisture measured |
| mix_identifier | string | the concrete mix or supply identifier |
| age_at_test_days | integer | the specimen's age when tested |
| competent_person | string | the competent person responsible for the test |
| drawing_revision | string | the revision of that drawing the test lot was built to, as the drawing register labels it; the rework drift rule compares it with the revision current on the lot's work date |
| inspection_level | string | the declared inspection and testing level, Level 1 or Level 2 |
| field_dry_density | number | the field dry density measured |
| testing_authority | string | whether a GITA or a GTA did the testing |
| specification_value | number | the acceptance criterion the result is judged against |
| reference_dry_density | number | the reference maximum dry density |
| optimum_moisture_content | number | the optimum moisture content |
JSON Schema
{
"$schema": "https://json-schema.org/draft/2020-12/schema",
"$id": "https://docs.demiton.io/registers/inspection_test_result/v1.json",
"title": "inspection_test_result contract v1",
"type": "object",
"required": [
"material",
"project",
"result_unit",
"result_value",
"test_method",
"tested_on"
],
"properties": {
"outlier": {
"type": "boolean",
"description": "whether the result was treated as an outlier",
"x-demiton-requiredness": "optional"
},
"project": {
"type": "string",
"description": "the project whose works were tested",
"x-demiton-requiredness": "required",
"x-demiton-reference": true
},
"complies": {
"type": "boolean",
"description": "whether the result meets the specification",
"x-demiton-requiredness": "optional"
},
"material": {
"type": "string",
"description": "what was tested, e.g. soil, concrete or aggregate",
"x-demiton-requiredness": "required"
},
"specimen": {
"type": "string",
"description": "the specimen type and geometry, or the mould used",
"x-demiton-requiredness": "optional"
},
"test_lot": {
"type": "string",
"description": "the test lot the result belongs to",
"x-demiton-requiredness": "optional"
},
"tested_on": {
"type": "string",
"description": "the date the test was performed",
"x-demiton-requiredness": "required",
"x-demiton-unit": "day",
"format": "date",
"x-demiton-type": "date"
},
"accredited": {
"type": "boolean",
"description": "whether the laboratory is accredited for the test",
"x-demiton-requiredness": "optional"
},
"laboratory": {
"type": "string",
"description": "the laboratory that did the test",
"x-demiton-requiredness": "optional"
},
"sampled_at": {
"type": "string",
"description": "when the sample was taken",
"x-demiton-requiredness": "optional",
"format": "date-time",
"x-demiton-type": "datetime"
},
"external_id": {
"type": "string",
"description": "the laboratory report or sample id",
"x-demiton-requiredness": "optional"
},
"result_name": {
"type": "string",
"description": "the quantity measured, e.g. compressive strength or dry density ratio",
"x-demiton-requiredness": "optional"
},
"result_unit": {
"type": "string",
"description": "the unit of the result, e.g. MPa or percent",
"x-demiton-requiredness": "required"
},
"test_method": {
"type": "string",
"description": "the method designation and year, e.g. AS 1012.9:2014",
"x-demiton-requiredness": "required"
},
"result_value": {
"type": "number",
"description": "the measured result",
"x-demiton-requiredness": "required",
"x-demiton-type": "decimal"
},
"curing_regime": {
"type": "string",
"description": "how the concrete specimen was cured",
"x-demiton-requiredness": "optional"
},
"defects_noted": {
"type": "string",
"description": "specimen defects recorded at test",
"x-demiton-requiredness": "optional"
},
"test_location": {
"type": "string",
"description": "where on the works the test or sample was taken",
"x-demiton-requiredness": "optional"
},
"drawing_number": {
"type": "string",
"description": "the drawing the test lot was built to, as the drawing register numbers it; the rework drift rule joins the lot to the drawing's revision history on it",
"x-demiton-requiredness": "optional",
"x-demiton-reference": true
},
"field_moisture": {
"type": "number",
"description": "the field moisture measured",
"x-demiton-requiredness": "optional",
"x-demiton-unit": "percent",
"x-demiton-type": "decimal"
},
"mix_identifier": {
"type": "string",
"description": "the concrete mix or supply identifier",
"x-demiton-requiredness": "optional"
},
"age_at_test_days": {
"type": "integer",
"description": "the specimen's age when tested",
"x-demiton-requiredness": "optional",
"x-demiton-unit": "days"
},
"competent_person": {
"type": "string",
"description": "the competent person responsible for the test",
"x-demiton-requiredness": "optional",
"x-demiton-reference": true
},
"drawing_revision": {
"type": "string",
"description": "the revision of that drawing the test lot was built to, as the drawing register labels it; the rework drift rule compares it with the revision current on the lot's work date",
"x-demiton-requiredness": "optional"
},
"inspection_level": {
"type": "string",
"description": "the declared inspection and testing level, Level 1 or Level 2",
"x-demiton-requiredness": "optional"
},
"field_dry_density": {
"type": "number",
"description": "the field dry density measured",
"x-demiton-requiredness": "optional",
"x-demiton-unit": "t/m3",
"x-demiton-type": "decimal"
},
"testing_authority": {
"type": "string",
"description": "whether a GITA or a GTA did the testing",
"x-demiton-requiredness": "optional"
},
"specification_value": {
"type": "number",
"description": "the acceptance criterion the result is judged against",
"x-demiton-requiredness": "optional",
"x-demiton-type": "decimal"
},
"reference_dry_density": {
"type": "number",
"description": "the reference maximum dry density",
"x-demiton-requiredness": "optional",
"x-demiton-unit": "t/m3",
"x-demiton-type": "decimal"
},
"optimum_moisture_content": {
"type": "number",
"description": "the optimum moisture content",
"x-demiton-requiredness": "optional",
"x-demiton-unit": "percent",
"x-demiton-type": "decimal"
}
},
"x-demiton-register-type": "inspection_test_result",
"x-demiton-contract-version": "1.2.0",
"x-demiton-store": "tenant",
"x-demiton-axes": [],
"x-demiton-measures": [],
"x-demiton-provenance": {
"standards": [
{
"code": "AS 1012 series",
"title": "Methods of testing concrete",
"access": "paywalled_secondary",
"clause": "AS 1012.9:2014 cl 4 (specimen defects to be noted per cl 11 and 12)",
"region": "Australia",
"edition": "series; parts separately dated (e.g. AS 1012.1:2014, 1012.8.1:2014, 1012.9:2014, 1012.14:2018)",
"checked_on": "2026-09-14"
},
{
"code": "AS 1289 series",
"title": "Methods of testing soils for engineering purposes",
"access": "paywalled_secondary",
"clause": "AS 1289.5.1.1:2017 cl 3.1 (competent person)",
"region": "Australia",
"edition": "series; umbrella AS 1289.0:2014; parts separately dated (e.g. AS 1289.5.1.1:2017, 5.2.1:2017, 5.4.1:2007, 5.8.1:2007)",
"checked_on": "2026-09-14"
},
{
"code": "AS 1379",
"title": "Specification and supply of concrete",
"access": "public_summary",
"region": "Australia",
"edition": "edition conflicting: index lists 2007 as current, a reseller advertised AS 1379:2026 (unverified)",
"checked_on": "2026-09-14"
},
{
"code": "AS 3798-2007",
"title": "Guidelines on earthworks for commercial and residential developments",
"access": "public_summary",
"clause": "s 3.5 site records; s 8.2-8.7 (Level 1/2, GITA, GTA, statements of compliance, frequency); App C4 outliers",
"region": "Australia",
"edition": "2007 incorporating Amd 1 (2008)",
"checked_on": "2026-09-14"
},
{
"code": "NATA accreditation",
"title": "National Association of Testing Authorities accreditation",
"access": "public_summary",
"region": "Australia",
"edition": "current",
"checked_on": "2026-09-14"
},
{
"code": "EN 12350 / EN 12390 / EN 13286",
"title": "European concrete and unbound-mixture test standards",
"access": "public_summary",
"region": "European Union",
"edition": "EN editions as adopted by BS/I.S.",
"checked_on": "2026-09-14"
},
{
"code": "ISO/IEC 17025:2017",
"title": "General requirements for the competence of testing and calibration laboratories",
"access": "public_summary",
"clause": "cl 7 process requirements (no sub-clause cited)",
"region": "International",
"edition": "2017",
"checked_on": "2026-09-14"
},
{
"code": "NZS 3112:1986",
"title": "Methods of test for concrete",
"access": "public_summary",
"region": "New Zealand",
"edition": "1986 (parts 3112.1, 3112.2)",
"checked_on": "2026-09-14"
},
{
"code": "NZS 4402:1986",
"title": "Methods of testing soils for civil engineering purposes",
"access": "public_summary",
"region": "New Zealand",
"edition": "1986 (parts 4402.1, 4402.4.1.1, 4402.5.1.1)",
"checked_on": "2026-09-14"
},
{
"code": "BS EN 12350 / BS EN 12390",
"title": "Testing fresh concrete / Testing hardened concrete",
"access": "public_summary",
"region": "United Kingdom",
"edition": "e.g. BS EN 12350-1:2019, -2:2019; BS EN 12390-1:2021, -2:2019, -3:2019, -4:2025, -5:2019",
"checked_on": "2026-09-14"
},
{
"code": "BS EN 13286 / BS 1377",
"title": "Unbound and hydraulically bound mixtures / Methods of test for soils for civil engineering purposes",
"access": "public_summary",
"region": "United Kingdom",
"edition": "BS EN 13286-1:2021, BS EN 13286-2:2010, BS 1377-9:2025",
"checked_on": "2026-09-14"
},
{
"code": "ASTM C172 / C31 / C39 / C143 / C231",
"title": "ASTM fresh and hardened concrete sampling and test methods",
"access": "public_summary",
"region": "United States",
"edition": "C172/C172M-25, C31/C31M-26a, C39/C39M-24, C143/C143M-26a, C231/C231M-26",
"checked_on": "2026-09-14"
},
{
"code": "ASTM D698 / D1557 / D6938 / D2216",
"title": "ASTM soil compaction, nuclear density and water content methods",
"access": "public_summary",
"region": "United States",
"edition": "D698-12, D1557-12, D6938-23, D2216-19",
"checked_on": "2026-09-14"
}
]
},
"description": "Soil and concrete test results (AS 1289, AS 1012).",
"x-demiton-contract-url": "https://docs.demiton.io/registers/inspection_test_result/",
"x-demiton-register-catalog": "https://docs.demiton.io/concepts/register-catalog"
}
Work with this as data
Every JSON Schema here is available over the APIs.io API and to AI agents over MCP.
MCP server
One button, every client — Claude, Cursor, VS Code and the rest.
https://apis.io/mcp
Tools for schemas
4 MCP tools reach this
find_json_schemasBrowse and filter every JSON Schema in the catalog.apis_io_searchSTART HERE — APIs, providers and tags for one query, each with its total.resolveTurn a domain, URL or GitHub org into the provider it belongs to.find_cohortsEvery scored population of providers in the catalog.
Call it yourself
curl for this page
This JSON Schema
curl "https://apis.io/api/v1/json-schemas/demiton-io-inspection_test_result-v1"
All schemas
curl "https://apis.io/api/v1/json-schemas?limit=25"
Calls without X-API-Key need no key. Calls with it need a paid plan — get a key.
Get an API key
Free tier, no form to fill in. Signing in shares your email address with us — we store it to create your key and to recognise you if you sign in with another provider. See our Privacy Policy and Terms.
A second provider on the same verified email joins the account you already have.