Inductive Automation config-system-properties API

System properties configuration

OpenAPI Specification

inductive-automation-config-system-properties-api-openapi.yml Raw ↑
openapi: 3.0.3
info:
  title: Ignition Gateway REST access-control config-system-properties API
  description: The Ignition Gateway REST API (Ignition 8.3+) provides an OpenAPI-compliant HTTP interface to Gateway configuration resources including tags, projects, modules, device connections, historian data, user management (SCIM), alarm notification, OPC connections, and more. The specification is dynamically generated based on installed modules. Authentication uses API keys exchanged for time-limited tokens via the X-Ignition-API-Token header. Mutative requests are audit-logged. Supports Kubernetes and Helm-based cloud-native deployments.
  version: 8.3.0
  contact:
    name: Inductive Automation Support
    url: https://support.inductiveautomation.com/
  license:
    name: Commercial
    url: https://inductiveautomation.com/pricing/
  x-postman-collection: https://raw.githubusercontent.com/inductiveautomation/83-api/main/postman/8.3.postman_collection_v2.json
servers:
- url: http://{gateway-host}:{port}
  description: Ignition Gateway (HTTP)
  variables:
    gateway-host:
      default: localhost
      description: Hostname or IP address of the Ignition Gateway
    port:
      default: '8088'
      description: Gateway HTTP port (default 8088; HTTPS default 8043)
- url: https://{gateway-host}:{port}
  description: Ignition Gateway (HTTPS)
  variables:
    gateway-host:
      default: localhost
      description: Hostname or IP address of the Ignition Gateway
    port:
      default: '8043'
      description: Gateway HTTPS port
security:
- apiKeyAuth: []
tags:
- name: config-system-properties
  description: System properties configuration
paths:
  /data/api/v1/homepage-notes:
    get:
      summary: Get Homepage Notes
      operationId: get-homepage-notes-get
      tags:
      - config-system-properties
      description: Returns the homepage notes text from Gateway Properties.
      responses:
        '200':
          description: Successful response
          content:
            application/json:
              schema:
                type: object
        '400':
          description: Bad request
        '401':
          description: Unauthorized
        '404':
          description: Not found
  /data/api/v1/resources/ignition/system-properties:
    put:
      summary: Modify System Properties
      operationId: modify-system-properties-put
      tags:
      - config-system-properties
      description: Modify one or more System Properties resources
      requestBody:
        content:
          application/json:
            schema:
              type: object
            example:
            - signature: <string>
              collection: <string>
              enabled: <boolean>
              description: <string>
              config:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
              backupConfig:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
            - signature: <string>
              collection: <string>
              enabled: <boolean>
              description: <string>
              config:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
              backupConfig:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
      responses:
        '200':
          description: Successful response
          content:
            application/json:
              schema:
                type: object
        '400':
          description: Bad request
        '401':
          description: Unauthorized
        '404':
          description: Not found
    post:
      summary: Create System Properties
      operationId: create-system-properties-post
      tags:
      - config-system-properties
      description: Create the System Properties resource
      requestBody:
        content:
          application/json:
            schema:
              type: object
            example:
            - collection: <string>
              enabled: <boolean>
              description: <string>
              config:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
              backupConfig:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
            - collection: <string>
              enabled: <boolean>
              description: <string>
              config:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
              backupConfig:
                systemName: <string>
                designerRAM: MB1024
                disable3DPipeline: true
                disableDirectDraw: false
                useCondensedDialogFont: false
                homepageUrl: /app
                homepageNotes: Welcome to your Ignition Gateway. This customizable area is intended to capture the critical details you want to document for this Gateway. You might include information about the environment (production, testing, or development), key workflows, or maintenance schedules. It's also a great place to list instructions for your team, important reminders about system health, or details about your configuration that require regular review. Use this space to keep everyone informed and ensure smooth operations across the board.
                clientFallbackEnabled: false
                secondsBeforeFailover: 60
                fallbackProjectName: <string>
                scheduledBackupsEnabled: false
                scheduledBackupPath: <string>
                scheduledBackupTimes: 15 1 * * *
                scheduledBackupRetentionCount: 5
                scheduledBackupFilename: ${gatewayName}_Ignition-backup-${edition}${timestamp}.gwbk
                automaticThreadDumpsEnabled: false
                automaticThreadDumpsIntervalSeconds: 60
                automaticThreadDumpsCpuThreshold: 70
                automaticThreadDumpsCpuThresholdExceededDuration: 10
                automaticThreadDumpsRetentionCount: 50
                errorReportSMTPServer: <string>
                errorReportToEmail: <string>
                errorReportFromEmail: <string>
                errorReportUsername: <string>
                errorReportPassword:
                  type: <string>
                  data:
                    protected:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    encrypted_key:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    iv:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    ciphertext:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                    tag:
                      value: '<Error: Too many levels of nesting to fake this schema>'
                multicastEnabled: true
                multicastIPAddr: 231.1.1.1
                multicastSendPort: '4445'
                multicastReceivePort: '4446'
                multicastIntervalMillis: '5000'
                gatewayScriptingProject: <string>
                enableTagReferenceStore: true
                scriptMessageEncoding: Protobuf
      responses:
        '200':
          description: Successful response
          content:
            application/json:
              schema:
                type: object
        '400':
          description: Bad request
        '401':
          description: Unauthorized
        '404':
          description: Not found
  /data/api/v1/resources/ignition/system-properties/{signature}:
    delete:
      summary: Delete System Properties
      operationId: delete-system-properties-delete
      tags:
      - config-system-properties
      description: Delete the System Properties resource.
      parameters:
      - name: signature
        in: path
        required: true
        schema:
          type: string
      - name: collection
        in: query
        required: false
        schema:
          type: string
        description: The configuration collection to delete the resource from
      responses:
        '200':
          description: Successful response
          content:
            application/json:
              schema:
                type: object
        '400':
          description: Bad request
        '401':
          description: Unauthorized
        '404':
          description: Not found
  /data/api/v1/resources/singleton/ignition/system-properties:
    get:
      summary: Get System Properties Config
      operationId: get-system-properties-config-get
      tags:
      - config-system-properties
      description: Retrieve configuration details about the System Properties resource
      parameters:
      - name: defaultIfUndefined
        in: query
        required: false
        schema:
          type: string
        description: If true, return the default configuration if the resource is not defined. Otherwise, return 404. Default is false.
      - name: collection
        in: query
        required: false
        schema:
          type: string
        description: The configuration collection to read the resource from
      responses:
        '200':
          description: Successful response
          content:
            application/json:
              schema:
                type: object
        '400':
          description: Bad request
        '401':
          description: Unauthorized
        '404':
          description: Not found
  /data/api/v1/resources/type/ignition/system-properties:
    get:
      summary: Describe 'System Properties' Resource Type
      operationId: describe-'system-properties'-resource-type-get
      tags:
      - config-system-properties
      description: Describe the System Properties resource type
      responses:
        '200':
          description: Successful response
          content:
            application/json:
              schema:
                type: object
        '400':
          description: Bad request
        '401':
          description: Unauthorized
        '404':
          description: Not found
components:
  securitySchemes:
    apiKeyAuth:
      type: apiKey
      in: header
      name: X-Ignition-API-Token
      description: Time-limited API token. Obtain by posting credentials to the token endpoint. See /data/api/v1/token for details.
externalDocs:
  description: Ignition 8.3 Gateway REST API Documentation
  url: https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/openapi